Question 1 of 10
1. Question
The proficiency of warming is more for?
Correct
In electrical heating, waste of energy would be minimum causing more efficiency.
Incorrect
In electrical heating, waste of energy would be minimum causing more efficiency.
-
Question 2 of 10
2. Question
A decent warming component ought to have?
Correct
As these components have to perform at high temperatures so it would have high resistivity and high softening points.
Incorrect
As these components have to perform at high temperatures so it would have high resistivity and high softening points.
-
Question 3 of 10
3. Question
The technique for warming utilized in an electric room heat convector is?
Correct
In the electrical process, resistance causes heating and this property of resistance is used to for achieving high temperatures.
Incorrect
In the electrical process, resistance causes heating and this property of resistance is used to for achieving high temperatures.
-
Question 4 of 10
4. Question
On the off chance that a heater is to warm temperatures around 1500°C, which of the accompanying material for warming components ought to be chosen?
Correct
The softening purpose of Eureka is 1221 to 1300 °C. The softening purpose of Kanthal is 1,425 °C. The softening purpose of Nichrome is 1400 °C. Molybdenum mixes (about 14% of world creation of the component) are utilized in high-pressing factor and high-temperature applications as colors and impetuses. The liquefying purpose of the platinum-molybdenum carbon compound is around 3000°C.
Incorrect
The softening purpose of Eureka is 1221 to 1300 °C. The softening purpose of Kanthal is 1,425 °C. The softening purpose of Nichrome is 1400 °C. Molybdenum mixes (about 14% of world creation of the component) are utilized in high-pressing factor and high-temperature applications as colors and impetuses. The liquefying purpose of the platinum-molybdenum carbon compound is around 3000°C.
-
Question 5 of 10
5. Question
Which of the accompanying will occur if the thickness of the stubborn mass of the heater is expanded?
Correct
In a heater we need to have high warmth move inside the heater; nonetheless, we don’t need any warmth misfortune through the heater divider. Consequently to forestall the warmth move from the heater to the air an awful warmth conductor or an awesome warmth protector is required. On account of the heater, the divider is set up by different layers of hard-headed materials to limit the warmth misfortunes. In this way, divider protection is needed to limit the warmth misfortune from the framework to the climate or warmth acquire from the climate to the framework.
Incorrect
In a heater we need to have high warmth move inside the heater; nonetheless, we don’t need any warmth misfortune through the heater divider. Consequently to forestall the warmth move from the heater to the air an awful warmth conductor or an awesome warmth protector is required. On account of the heater, the divider is set up by different layers of hard-headed materials to limit the warmth misfortunes. In this way, divider protection is needed to limit the warmth misfortune from the framework to the climate or warmth acquire from the climate to the framework.
-
Question 6 of 10
6. Question
Which of the accompanying techniques is best for inspecting surface imperfections on the castings?
Correct
Visual assessment is a kind of non – damaging testing method that gives a method for distinguishing and analyzing the assortment of surface imperfections, for example, surface completion, discontinuities, and surface breaks on the castings. This strategy is exceptionally modest and broadly utilized in light of the fact that a large portion of the surface deformities and unpleasantness can be noticed without any problem.
Incorrect
Visual assessment is a kind of non – damaging testing method that gives a method for distinguishing and analyzing the assortment of surface imperfections, for example, surface completion, discontinuities, and surface breaks on the castings. This strategy is exceptionally modest and broadly utilized in light of the fact that a large portion of the surface deformities and unpleasantness can be noticed without any problem.
-
Question 7 of 10
7. Question
Which of the accompanying sorts of light is liked for utilizing fluorescent penetrant in fluid penetrant testing (LPT) strategy?
Correct
In the LPT strategy, the goal is cultivated by the capture of the assessment fluid by the blemishes followed by a visual review of the surface under UV light (when utilizing a fluorescent penetrant) and for obvious color penetrant, ordinary light can be utilized for the investigation cycle.
Incorrect
In the LPT strategy, the goal is cultivated by the capture of the assessment fluid by the blemishes followed by a visual review of the surface under UV light (when utilizing a fluorescent penetrant) and for obvious color penetrant, ordinary light can be utilized for the investigation cycle.
-
Question 8 of 10
8. Question
Which of the following is the right assertion about surrendering warmth from one medium to another in the alkali ingestion framework?
Correct
Surrendering heat from a medium to specifically in alkali ingestion would feeble response for strong settings.
Incorrect
Surrendering heat from a medium to specifically in alkali ingestion would feeble response for strong settings.
-
Question 9 of 10
9. Question
Which of the following is the COP of a fume pressure plant in contrast with a fume assimilation plant?
Correct
COP of vapor pressure as compared to the vapor assimilation plant would be more.
Incorrect
COP of vapor pressure as compared to the vapor assimilation plant would be more.
-
Question 10 of 10
10. Question
The diminished surrounding air cooling framework is using which of the following property?
Correct
Less area to dissipate heat structure would require two cooling turbines plus a heat exchanger.
Incorrect
Less area to dissipate heat structure would require two cooling turbines plus a heat exchanger.